Loading 30 lb. (13.6 kg) Readi-Reels
(See Figure A.11)

A K363-P Readi-Reel adapter is required for loading
these spools on 2" (51mm) spindles.

1. Squeeze the release bar on the retaining collar and

remove it from the spindle.

2. Place the Readi-Reel adapter on the spindle, align-

ing the spindle brake pin with one of the holes in the
adapter.

3. Re-install the retaining collar. Make sure that the

release bar snaps out and that the retaining collar
fully engages the groove on the spindle.

4. Rotate the spindle and adapter until the retaining

spring is at the 12 o’clock position.

5. Position the Readi-Reel so that electrode de-reels in

the proper direction.

6. Set one of the Readi-Reel inside cage wires on the

slot in the retaining spring.

7. Lower the Readi-Reel to depress the retaining

spring and align the other inside cage wires with the
grooves in the adapter.

8. Slide the cage all way onto the adapter until the

retaining spring "pops up" fully.

Removing a Readi-Reel

1. To remove a Readi-Reel from the an adapter,

depress the retaining spring with a thumb while
pulling the Readi-Reel cage from the adapter with
both hands. Do not remove the adapter from the
spindle.

WELD WIRE ROUTING

The electrode supply may be either from reels, Readi-
Reels, spools, or bulk packaged drums or reels.
Observe the following precautions:

a) The electrode must be routed to the wire drive unit

so that the bends in the wire are at a minimum,
and also that the force required to pull the wire
from the reel into the wire drive unit is kept at a
minimum.

b) The electrode is “hot” when the gun trigger is

pressed and must be insulated from the boom and
structure.

c) If more than one wire feed unit shares the same

boom and are not sharing the some power source
output stud, their wire and reels must be insulated
from each other as well as insulated from their
mounting structure.

SPINDLE

BRAKE

PIN

GROOVES

ADAPTER

RETAINING

SPRING

READI-

REEL

CAGE

WIRE

RELEASE

BAR

RETAINING

COLLAR

FIGURE A.11