K1500-4 (MILLER CONNECTION)

For any gun having a newer style Miller connector.
Install gun adapters per the instructions shipped with it.

K1500-5 (OXO CONNECTION)

For any gun having an OXO style connector. Install
gun adapters per the instructions shipped with it.

CONDUIT ADAPTERS

K1546-2 ADAPTER

for use with Lincoln Magnum conduit and E-Beam con-
duit (wire sizes 1/16 - .120)

For Magnum conduit:

Install the K1546-2 gun adapter at the incoming end of
the feed plate, secure with the set screw located at the
back of the feed plate. If a brass fitting is supplied with
the conduit, remove it from the feeder end of the con-
duit by unscrewing it. Insert the conduit into the K1546-
2, secure the conduit by fastening it the the adapter
with the supplied knob screw.

For E-Beam Conduit:

Install the K1546-2 gun adapter at the incoming end of
the feed plate, secure with the set screw located at the
back of the feed plate. Insert the conduit into the
K1546-2, secure the conduit by fastening it the the
adapter with the supplied knob screw.

DUAL

PROCEDURE SWITCH

OPTIONS

K683-3 DUAL PROCEDURE SWITCH

Kit includes gun switch, and mountings for Lincoln
Innershield and Magnum guns, with 15 ft. (4.5m) con-
trol cable and 5-pin plug with two leads to connect to
gun trigger.

Connect the 5-pin plug of the K683-3 Dual procedure
Switch to the Power Feed 10 Dual Wire Feeder
Trigger/Dual Procedure 5-socket receptacle.

The two lead plug cord extending out of the 5-pin plug
of the Dual Procedure switch is to be connected to the
two trigger leads of the welding gun per instructions
shipped with the kit.

K683-1 DUAL PROCEDURE SWITCH

The K683-3 Dual Procedure Switch is the recommend-
ed method of obtaining dual procedure for non-Fast-
Mate guns; but a K683-1 can be used. For using a
K683-1 with a fast mate gun, see USING DUAL PRO-
CEDURE WITH FAST-MATE GUNS. A K683-1 Dual
Procedure Switch can be used on the Power Feed 10
Dual if a K686-2 adapter is used. The K686-2 kit
includes the gun switch and mountings for Lincoln
Innershield and Magnum guns, with 15 ft. (4.5 m) con-
trol cable and 3-pin plug. K686-2 Adapter permits the
3-pin plug from the K683-1and 5-pin gun trigger plug to
be connected to the 5-pin trigger/dual procedure
receptacle on the wire feeder.

USING DUAL SCHEDULE WITH FAST-
MATE GUNS ON -10 SERIES FEEDERS

Configuration 1

K489-7 Dual Schedule Fast-Mate adapter

K575-[ ] Magnum 400 DS/FM gun (or competitive
DS/FM gun)

Configuration 2

*

K489-7 Dual Schedule Fast-Mate adapter
K683-1 Dual Procedure Switch (3 pin)
K686-2 "Y" adapter (3pin + 5 pin to 5 pin)

* Non-DS Fast-Mate gun (Magnum 450WC, Magnum 200, Magnum 300,
Magnum 400, and others)

K590-6 WATER CONNECTION KIT

Install per the instructions shipped with the kit.

K1536-1 WATER FLOW SENSOR KIT

Install per the instructions shipped with the kit

Advertising