Operation – Lincoln Electric POWER FEED 10M SINGLE/DUAL SVM172-A User Manual

Page 32

Advertising
background image

POWER FEED 10M SINGLE/DUAL

OPERATION

B-10

B-10

Re

tu

rn

to

Se

ct

io

n

T

O

C

Re

tu

rn

to

Se

ct

io

n

T

O

C

Re

tu

rn

to

Se

ct

io

n

T

O

C

Re

tu

rn

to

Se

ct

io

n

T

O

C

Re

tu

rn

to

Ma

st

e

r

T

O

C

Re

tu

rn

to

Ma

st

e

r

T

O

C

Re

tu

rn

to

Ma

st

e

r

T

O

C

Re

tu

rn

to

Ma

st

e

r

T

O

C

SETUP FEATURES MENU

The Setup Menu gives access to the set-up configuration.
Stored in the setup configuration are user parameters that
generally need to be set only at installation. The parameters
are grouped as follows:

• P.1 through P.99 Unsecured Parameters (always

adjustable)

• P.101 through P.199

Diagnostic Parameters (always

read only)

• P.501 through P.599

Secured Parameters (accessible

only though a p.c. or palm application.)

To access the setup menu, press the right and left buttons of
the MSP4 panel simultaneously. Note that the setup menu
cannot be accessed if the system is welding, or if there is a
fault (The status LED is not solid green).

Change the value of the blinking parameter rotating the SET
knob.

To exit the setup menu at any time, press the right and left
buttons of the MSP4 panel simultaneously. Alternately, 1
minute of inactivity will also exit the setup menu.

The following list includes all possible parameters in
ArcLink equipment. Not all of the parameters listed may
appear for your system. Refer to the (TABLE B.1) for
active parameters.

LIMIT SETTING

The MSP4 can be optionally configured to limit the operator’s
range of control of any weld parameter (weld WFS, arc con-
trol, etc.). Limits are only available with the Dual
Procedure/Memory Panel.

MACHINE SETUP/USER PREFERENCES

The MSP4 can be used to configure and troubleshoot the
machine.

ACCESSING THE MACHINE SETUP MENU

To access the Machine Setup menu, press both MSP4 push
buttons simultaneously. The MSP4 7-segment display will
display the first user preference, "P.0", and the SETUP LED
will illuminate.

• Pressing the left MSP4 pushbutton will exit the entire

Machine Setup menu while in the P.0 user preference.

• Turning the MSP4 encoder knob will select other available

User Preferences.

• To exit the User Preference Menu, either rotate the MSP4

encoder until P.0 is displayed and press the left MSP4
pushbutton or press both MSP4 push buttons simultane-
ously at any time.

PARAMETER

P.0
P.1
P.2
P.3
P.4
P.5
P.6
P.7
P.8
P.9

P.11

P.12
P.13
P.80
P.99

DESCRIPTION

Exit set-up menu

WFS Units

Arc Display Mode

Display Power

Trigger Memory Recall

Trigger Procedure Change

Stall Factor Adjustment

Gun Offset Adjustment

TIG Gas Control

Crater Delay

Set Timers

Travel Options

Adjust Arc Force

Sense From Studs

Show Test Modes

View Diagnostics

View Event Logs

View Fatal Logs

View Software Version

View Hardware Version

View Welding Software

View Ethernet IP Address

View Power Source Type

P.100
P.101
P.102
P.103
P.104
P.105
P.106
P.107

Unsecured Parameters

Diagnostic Parameters

PF*-10M (All Models)

































PF*-15M



PF*-10A





TABLE B.1

* PF= POWER FEED

Advertising