• Input rating: Low-active, non-voltage normally open (N.O.) contact
• Output rating for pin # 4 ALARM RECOVERY 1* OUT: High-active with a 200

resistor pulled up to + 5 V

• Output rating for pin # 7 ALARM 2* OUT: High-active with a 4.7 k

resistor pulled up to + 12 V.

• Output rating for other pins: Low-active, maximum load capacity of 24 V 100 mA , open-collector with a 4.7 k

resistor

pulled up to +5 V inside

Alarm Connection

There are eight alarm inputs while two outputs are provided with different driving capacity.

External Recording Connection

The recording mode will change from the internal timer mode to the external mode (EXT REC MODE) specified in REC SETUP
menu, while turning on the switch.

Time Adjusting Connection

Internal timer is calibrated with this input.

Sensor

Door Switch

Alarm Input Terminals

Sinal Ground Terminals

#7 Alarm Output 2 *2

External
Alarm
Reset Switch

#2 Alar

m 1 In

#3 Alar

m 2 In

Relay *1

Alarm Indicator

*1: Use when the indicator exceeds over the drive capacity of the alarm out terminal.
*2: Connect to #6 ALARM OUT 1 when using a low-active device.

#22 External Recording Mode

Master Clock

Non-voltage N.O. Contact
N.O.=Normally Open