Setup control, Miscellaneous control, Data log control – Panasonic WJ-HD200 User Manual
Page 83: Media control
84
Setup Control
Item
Transmission Command (ASCII)
Response (ASCII)
Parameter (ASCII)
Cursor Moves
DCR:n1n2
DCR
n1=A Right
n1=C Upward
n1=E Left
n1=G Downward
n2=1 Move a step
n2=2 Move multi steps
n1n2=PD Move to lower layer
n1n2=P+ Move to upper layer
n1n2=P- Turn a newer page
n1n2=PU Turn an older page
Key Lock
MKL:n
MKL
n=0 Lock OFF
n=1 Lock ON
Recording Event
MRM:n
MRM
n=0 Normal recording
Setup
n=1 Internal timer recording
n=2 External timer recording
Summer Time Setup
MST:n
MST
n=0 Standard time
n=1 Summer time
Setup
MSU:n
MSU:n
n=0 End setup
n=1 Begin setup
Date&Time Setup
TSU:yyyymmddhhnn
TSU
yyyy=Year
mm=Month
dd=Day
hh=Hour (24-hour system)
nn=Minute
Miscellaneous Control
Item
Transmission Command (ASCII)
Response (ASCII)
Parameter (ASCII)
OSD Show/Hide
DIN:n
DIN
n=+ Toggle
n=0 Hidden
n=1 Shown
Communication Check RCK
RCK
Time&Date Search
ZTS:yyyymmddhhnnss
ZTS
yyyy=Year
mm=Month
dd=Day
hh=Hour (24-hour system)
nn=Minute
ss=Second
Data Log Control
Item
Transmission Command (ASCII)
Response (ASCII)
Parameter (ASCII)
Log Total Size Inquiry
ILB:k
ILB:k:bbbbb
k=0 Alarm log
bbb=001 to 099 (in decimal)
Log Erase
ILC:n
ILC:n
n=0 Alarm log
n=1 System log
Log Recorded
ILQ:k
ILQ:k:bbbbb:ddddd:(:E)
k=0 Alarm log
Size Inquiry
bbbbb=00001 - 00999 (Oldest log)
ddddd=00001 - 00999 (Size of log)
E=Overwrite
Log Readout
ILR:k:sss:mmm
ILR:k:<log data s1>s1
k=0 Alarm log
<log data s2>s2
sss=001-2 000 Start Address
<log data sn>F
mmm=001-100 Decimal # of log
<log data sn>=yymmddhhnnss
sn=0-9 and F
Cyclic number
(F is put at data end)
Media Control
Item
Transmission Command (ASCII)
Response (ASCII)
Parameter (ASCII)
Disk End Notice Setup
MDE:n
MDE
n=0 End is not notified
n=1 End is notified
Disk End Notice
HDE