Communication setup communication setup, Serial port setup serial port setup, Protocol selection (protocol select) – Panasonic WJ-HD200 User Manual

Page 63: Baud rate (baud rate), Data bit (data bit), Parity check (parity check), Stop bit (stop bit), Wait time (wait time), Alarm data (alarm data)

Advertising
background image

64

8

Parity Check (PARITY CHECK)

NONE:

No parity check

EVEN:

Even parity

ODD:

Odd parity

8

Stop Bit (STOP BIT)

1 bit:

1 bit

2 bit:

2 bits

8

Wait Time (WAIT TIME)

OFF:

Retransmission is disabled.

100 MSEC:

100 m seconds

200 MSEC:

200 m seconds

1 SEC:

1 second

8

System Unit Address (SYSTEM UNIT ADDRESS)
(only for PS

DATA)

Assignable address:

From 1 to 99, must be unique in

the chain.

8

Control Unit Address
(CONTROL UNIT ADDRESS) (only for PS

DATA)

Assignable address:

From 1 to 99, must be unique in

the chain.

8

Alarm Data (ALARM DATA)

OFF:

Select this when no system controller is connect-

ed.

0 SEC:

Pauses no time.

1 SEC:

Pauses for 1 second.

5 SEC:

Pauses for 5 seconds.

Click the [SET] button if all are adequately set.

Click the [CAMERA NO. SETUP] button. The CAMERA NO.
SETUP window opens.

Communication Setup
COMMUNICATION SETUP

Click the [SERIAL SETUP], or [NETWORK SETUP] button.
The respective window opens.

Serial Port Setup

SERIAL PORT SETUP

8

Protocol Selection (PROTOCOL SELECT)

PS

DATA:

Select when the communication chain uses

the PS

DATA protocol.

When selected, the DATA terminal on the rear panel
can be used.

VCR:

Select when other than PS

DATA is used.

When selected, the RS-232C terminal on the rear
panel can be used.

8

Baud Rate (BAUD RATE)

4800:

4 800 bps

9600:

9 600 bps

19200:

19 200 bps

8

Data Bit (DATA BIT)

7:

7 bits

8:

8 bits; select 8 when using the VCR protocol.

Advertising