Communication setup communication setup, Serial setup serial setup, Protocol protocol – Panasonic WJ-HD200 User Manual

Page 36

Advertising
background image

36

Notes:

• VMD should be used with an ordinary camera input

to the unit. Select [OFF] to avoid useless VMD when
a video multiplexer or combination camera supplies
the input to the unit.

• Set the ALARM SUSPEND to ON when VMD is

unnecessarily activated during the VMD setup.

4. Set the upper-left end of the detection area. Move the

asterisk to the right or left with the JogDial, and up or
down by pressing the [D] or [C] button.

5. Press the JogDial to enter the upper-left end of the

detection area. The asterisk position is highlighted.

6. Set the bottom-right end of the detection area similar to

steps 3 and 4 above.

7. Press the JogDial. The area is highlighted.

Up to 4 areas can be selected. These may partially
overlap. Repeat steps 3 to 6 to select more areas. To
deselect an area, move the cursor to the upper-left end
of the area, and press the JogDial.

Communication Setup
COMMUNICATION SETUP

Communication parameters are set to match those of the
connected devices and the system configuration. The serial
port setup and network setup are made.

Serial Setup SERIAL SETUP

The SERIAL SETUP menu appears when it is selected in
the COMMUNICATION SETUP menu.

Note:

Parameters marked with * in the following pages are

default settings applied to VCR.

Protocol PROTOCOL

1. Move the cursor to PROTOCOL with the [D] or [C] but-

ton.

2. Select a suitable protocol with the JogDial, and press

the JogDial.
The default is PS

DATA.

PS

DATA:

Select when the communication chain uses

the PS

DATA protocol.

This selection enables the DATA terminal on the
rear panel for communication.

VCR:

Select when other than PS

DATA is used.

This selection enables the RS-232C terminal on the
rear panel for communication.

Note:

Parallel use of the DATA and RS-232C terminals

is not possible.

*

CAM1

PUSH

PAUSE

/

/

SET

REW/FF

/

STEP

/

q

w

e

r

SERIAL SETUP

PROTOCOL PS•DATA
BAUD RATE 9600
DATA BIT 8
PARITY CHECK NONE
STOP BIT 1
WAIT TIME OFF
CTL-UNIT ADDR 1
SYS-UNIT ADDR 1
ALARM DATA 1S
CAM NO.SETUP

O

COMMUNICATION SETUP

SERIAL SETUP

O

NETWORK SETUP

O

Advertising