– 148 –

Key

F1

F2

F3

F4

F5

F6–F7

F8

F9–F13

Key designation

RED LAMP

——

REMOTE

SUPER

ERR LOG

——

EXIT

——

Description

For selecting the lighting specifications for the red lamp on the
front panel. When this lamp is lighted, the superimposed warning
display, error log recording and remote output connectors
(RS-232C/RS-422/PARALLEL) are also linked.
LEVEL0: . . . (Setting for enhanced detection sensitivity: The red

lamp lights even when one error occurs.)

LEVEL1: . . . (Standard factory setting)
LEVEL2: . . . (Setting with slightly reduced detection sensitivity)
LEVEL3: . . . (Setting with further reduced detection sensitivity)

For selecting whether to output or mask the warning amber
information (CONCEAL_A, CONCEAL_V, HIGH_ERROR_RATE)
of the RS-232C, RS-422 and PARALLEL output connectors.
When the red lamp is lighted, the information is output regardless
of which setting has been selected for this item.
ACTIVE: When the amber warning lamp on the front panel is

lighted, the information is also output to the external
remote.

MASK:

Even when the amber warning lamp on the front panel
is lighted, the information is not output to the external
remote.

For selecting whether to output or mask the superimposed
warning amber information (CONCEAL_A, CONCEAL_V,
HIGH_ERROR_RATE). When the red lamp is lighted, the
information is output regardless of which setting has been
selected for this item.
ACTIVE: When the amber warning lamp on the front panel is

lighted, the superimposed information is displayed.

MASK:

Even when the amber warning lamp on the front panel
is lighted, the superimposed information is not
displayed.

For selecting whether to record the warning amber information
(CONCEAL_A, CONCEAL_V, HIGH_ERROR_RATE) in the
error log or mask it. When the red lamp is lighted, the information
is recorded in the error log regardless of which setting has been
selected for this item.
ACTIVE: When the amber warning lamp on the front panel is

lighted, the information is stored in the error log.

MASK:

Even when the amber warning lamp on the front panel
is lighted, the information is not stored in the error log.

For returning operation to the ENGINEER SET UP menu.

RF ENGINEER SET UP menu

The Conceal V warning sensitivity and warning display output are set on this menu.

The underlining indicates the factory setting.