– 162 –

SERVO TEST menu

Key

F1

F2

F3

F4

F5

F6

F7

F8

F9

F10

F11

F12

F13

Key designation

TORQUE
Reel torque adjustment.

DATA SEND
Torque data forwarding.

MEASURE
(Measure)

AT
AT head adjustment.

METER

PG SHIFT
PG shifter adjustment.

ADJ RATE
Adjust rate.

EXIT

MECHA
Mechanical adjustment.

TRACKING
Tracking adjustment.

X VALUE

BIMORPH INIT
Removal of hysteresis at
AT voltage element.

ADJ ENABLE

Description

Key for adjustment by service personnel.

Key for adjustment by service personnel.

Key for adjustment by service personnel.

Key for adjustment by service personnel.

ERROR: Displays inner error level.
ENV:

Displays envelop level.

Key for adjustment by service personnel.

Key for adjustment by service personnel.

Returns the VTR to the TEST menu screen.

Key for adjustment by service personnel.

Under normal conditions, tracking adjustment is not necessary.
Adjust if there are tracking discrepancies while editing.
VAR:

Tracking is adjusted manually. Refer to “Manually
adjusting the tracking” (page 106).

FIX:

Tracking is fixed at the center position of the
manual adjustment.

OPT. ONCE: Tracking is optimized only once while the tape is

playing up to the IN point during the first editing
after the cassette has been inserted. Thereafter,
optimization does not take place. However,
optimization can be performed again. Refer to
“Automatically adjusting the tracking” (page 100).

OPT. AUTO: Tracking is optimized while the tape is playing up

to the IN point with each editing. Refer to
“Automatically adjusting the tracking” (page 105).

Key for X value adjustment by service personnel.

Key for adjustment by service personnel.

Key for adjustment by service personnel.