5 fault management, 1 alarm/event – Planet Technology IDL-2402 User Manual

Page 184

Advertising
background image

4.7.5 Fault Management

4.7.5.1 Alarm/Event

This option allows you to query current alarm, history alarm, and event log. From the
Maintenance menu, click on Fault Management and then Alarm/Event. The Current
Alarm
page is displayed. Click on the Alarm/Event Select drop-down list and select
Current Alarm, History Alarm, or Event Log to view.

Current Alarm:

Type in the range of rows (1 ~ 1024) and then click on the Query button.

Current Alarm Table

Label

Description

Query

Click on this button to get most recent data.

Row

This field shows the row number.

ID

This field shows the alarm ID.

Description

This field shows the description for the alarm.

Level

This field shows the alarm level. Valid values are:

MJ: major alarm. MN: minor alarm.

State

This field shows the alarm state: Set or Clear.

Sequential

Sequential number.

Time

Alarm occurring date and time.

- 184 -