4 mode, 5 noise, 6 noisemargin – Planet Technology IDL-2402 User Manual

Page 353: 4 mode 5.18.5 noise 5.18.6 noisemargin

Advertising
background image

- 353 -

5.18.4 mode

Description Set downstream/upstream rate adaptive mode to init (rate

automatically selected at start up only and does not change after that),

dynamic (rate automatically selected at initialization and is

continuously adapted during show time), or manual (rate changed

manually)

Syntax

mode {ds | us} {init | dynamic | manual}

Parameter None

5.18.5 noise

Description Set downstream/upstream minimum impulse noise protection.

Syntax

noise {ds | us} <number>

Parameter

Name

Description

number

Noise (tenth symbols).

Valid values: 0~8 step 0.1

Default value: -

Type: Mandatory

5.18.6 noisemargin

Description Set Downshift/Upshift Noise Margin in downstream/upstream

direction

Syntax

noisemargin {ds | us} {downshift | upshift} <number>

Parameter

Name

Description

number

Downshift/Upshift Noise Margin (tenth

symbols).

Valid values: 0~31 step 0.1

Default value: -

Type: Mandatory

Advertising