5.4.119 tcm yellow

Description

Set TCM yellow color value

Syntax

tcm yellow <number>

Parameter

Name

Description

<number>

TCM yellow color value

Valid values: 0 ~ 7 for VLAN priority color
field;
0 ~ 63 for DSCP color field

Default value: 3

Type: Mandatory


5.4.120 temperature threshold

Description

Shelf temperature threshold

Syntax

temperature threshold {up | down | fan} <number>

Parameter

Name

Description

<number>

Temperature threshold value.

Valid values: up: -55~85

Down: -55~85

fan: -40~15

Default value: up: 65

down: 65

fan: -40

Type: Mandatory


5.4.121 temperature shelf time

Description

Shelf time

Syntax

temperature shelf time {up | down} <number>

Parameter

Name

Description

<number>

Shelf time value.

Valid values: 1~255

Default value: 10

Type: Mandatory