3–26

Configuring the Printer

Data Polarity

This parameter must be set to match the Data Polarity of your host computer.

Standard: Does not expect the host computer to invert the data.

Inverted: Expects the data received on the data lines from the host computer to

be inverted. Ones become zeros and vice versa.

Resp. Polarity

The Response Polarity parameter must be set to match the Response Polarity of

your host computer.

Standard: Does not invert the response signal.

Inverted: Inverts the response signal sent to host computer.

Busy On Strobe

Enable: Asserts a busy signal only when the print buffers are full.

Disable: Asserts a busy signal after each character is received.

Latch On Data

Specifies whether the data is read on the leading (default) or trailing edge of the

data strobe signal.

Prime Signal

Enable: The parallel port will do a warm start (reboot) if the host asserts the

Prime Signal.

Disable: The parallel port will not do a warm start (reboot) if the host asserts the

Prime Signal.

TOF Action

Reset : A form feed is done before a warm start when the Prime Signal is

asserted from the host. This setting is only used if the Prime Signal parameter is

asserted.