3–32

Configuring the Printer

The printer uses different response characters to represent buffer full and buffer

empty, depending on whether it is online or offline. These response characters

are listed in the following table:

Online State

Buffer State

Response Character

Online

Buffer Empty

CR

Buffer Full

3

Offline

Buffer Empty

0

Buffer Full

2

With the SERIES 1 CH protocol selected, if the printer receives a Series 1 poll

character from the host, the printer removes the poll character from its input data

stream and discards it. After a delay, called the poll delay, the printer replies to

the host by sending the appropriate response character, per the preceding table.

During a poll delay, if the printer receives another poll character, the printer

merely discards it. However, if a transition (from buffer full to buffer empty or from

online to offline) occurs during a poll delay, the printer sends the response

character appropriate to the new printer state at the end of the delay.

If you enable the Series 1 Idle parameter, then whenever the buffer is less than

75% full, the printer sends a response character to the host every two seconds.

You can select the poll character and the poll delay time from the printer control

panel. You can also enable or disable Series 1 Idle from the control panel.

Descriptions of these parameters start on page 3–71.

NOTE: When using the SERIES 1, 1 CH protocol, be careful with the

transmission of binary data (control codes, bit images, etc.) since

the printer discards poll characters.

SERIES 1, 2 CH

When you select the Series 1 with 2 Characters protocol, the printer behaves

exactly the same as the Series 1 with 1 Character protocol except that the printer

sends two-character responses to the host. These response characters are listed

in the following table:

Online State

Buffer State

Response Character

Online

Buffer Empty

1 CR

Buffer Full

3 CR

Advertising