Advertising
background image

3–28

Configuring the Printer

PI Ignored

The PI (Paper Instruction) signal controls vertical paper motion. It is dependent

on your host computer.

Enable: Ignores the PI signal and treats the data as characters or control codes.

Disable: Causes the printer to interpret the eight data lines as VFU commands

when the PI signal is true.

Data Polarity

This parameter must be set to match the Data Polarity of your host computer.

Standard: Does not expect the host computer to invert the data.

Inverted: Expects the data received on the data lines from the host computer to

be inverted. Ones become zeros and vice versa.

Resp. Polarity

The Response Polarity parameter must be set to match the Response Polarity of

your host computer.

Standard: Does not invert the response signal.

Inverted: Inverts the response signal sent to host computer.

Latch On Data

Specifies whether the data is read on the leading, middle (default), or trailing

edge of the data strobe signal.

Prime Signal

Enable: The parallel port will do a warm start (reboot) if the host asserts the

Prime Signal.

Disable: The parallel port will not do a warm start (reboot) if the host asserts the

Prime Signal.

Advertising