Setting up LAN Emulation

Basic Configuration and Setup

8-12

Centillion 1200N ATM Switch User Manual

NTP 297-8103-903

Adjust ILMI timing parameters. This is specific to a connection to an ATM-
NIC. Use the following values: Timer value = 5, Times of retry = 60 (default)
and Keepalive = 20.

8.

Before svcline can be turned on, you must:

SET signaling 00 0 5

SET signaling 03 0 5

9.

When connecting two switches together, one has to be set to Network side and
another set to User side. (In this example, 8550-LES is set to Network side;
therefore, 8550 must be set to User side.)

For PNNI interface port 00:

SET atmsig 00 0

Interface (network|0 user|1)? 1

T303 (1-255,default=4)? 4

T308 (1-511,default=30)? 30

T309 (1-511,default=90)? 90

T310 (1-255,default=10)? 10

T313 (1-255,default=4)? 4

T316 (1-511,default=120)? 120

T317 (1-255,default=60)? 60

T322 (1-255,default=4)? 4

T398 (1-255,default=4)? 4

T399 (1-511,default=14)? 4

UNI Version (UNI3.0|0 UNI3.1|1,default=3.0)? 3.0

10.

For UNI interface port 03:

SET atmsig 03 0

Interface (network|0 user|1)? 0

T303 (1-255,default=4)? 4

T308 (1-511,default=30)? 30

T309 (1-511,default=90)? 90

T310 (1-255,default=10)? 10

T313 (1-255,default=4)? 4

T316 (1-511,default=120)? 120

T317 (1-255,default=60)? 60

T322 (1-255,default=4)? 4

T398 (1-255,default=4)? 4

T399 (1-511,default=14)? 4

UNI Version (UNI3.0|0 UNI3.1|1,default=3.0)? 3.0

SET svcline 00 resume

SET svcline 03 resume

Re-set the signaling connection deleted
previously. A signaling connection is set
with VPI/VCI=0/5

Set UNI 3.0