Troubleshooting procedures, When alarm led is lighted (hardware error), Example of responses – Panasonic 1200N User Manual

Page 149: Troubleshooting procedures -5, When alarm led is lighted (hardware error) -5

Advertising
background image

Troubleshooting

Troubleshooting Procedures

Centillion 1200N ATM Switch User Manual

11-5

NTP 297-8103-903

Troubleshooting Procedures

When ALARM
LED is Lighted
(Hardware Error)

When the ALARM LED lights red while operating the ATM Switch, follow the
instructions below:

1.

Connect the MAT to the ATM Switch. (See

"Physical Connection of MAT"

on page 9-3

.)

1.

Turn on the MAT's power and set its communication parameters. (See

"Setting

the MAT" on page 9-6

.)

2.

Enter the

DISPLAY alarm

command from the MAT. The command should

be entered as follows:

DISPLAY alarm[RETURN]

3.

Response will be output. Determine the error and take the necessary action.
(See

"Error Messages" on page 11-11

.)

4.

Disconnect the MAT from the ATM Switch.

Example of Responses

Hardware Alarm

96.03.10 20:11:48 - Environment000001

96.03.12 12:33:21 - FAN 0

96.02.22 08:47:38 - FAN 1

96.02.07 15:56:08 - Power Unit 0

96.02.08 12:36:15 - CPUDiagnosis NG070002

96.10.13 21:02:40 - SwitchClock Alarm010002

96.03.24 05:32:20 - Line Board 0 Clock Alarm000001

96.07.18 02:03:49 - Line Card 0 OC3c/STM-1(MMF)Path Alarm010001