P

LASMA

M

ONITOR

05. Input Switch Change

Function

The external control equipment switches the
input of the display.

Transmission Data

CFH UA1 UA2 50H 01H DATA CKS

DATA : Input Select

01H : Video
07H : RGB1
08H : RGB2
0CH : RGB3
05H : HD/DVD
0FH : SCART

ACK

There is no ACK for which input was selected.
2FH UA1 UA2 50H 00H CKS

06. COLOR TEMP Select

Function

The external control equipment changes the
COLOR TEMP of the display.

Transmission Data

CFH UA1 UA2 00H 01H DATA00 CKS

DATA00

00H : HIGH
01H : LOW
02H : USER1
03H : USER2
04H : USER3
05H : USER4

ACK

6FH UA1 UA2 00H 01H DATA00 CKS

DATA00 :

00H : HIGH
01H : LOW
02H : USER1
03H : USER2
04H : USER3
05H : USER4

NOTE: When HIGH or LOW is selected with
COLOR TEMP, changes of the R/G/B GAIN data
will not be received.

07. RED Gain Data

Function

The external control equipment changes the
RED gain data of the display. (This command
will be received only when COLOR TEMP is
set for USER 1-4.)

Transmission Data

CFH UA1 UA2 10H 04H DATA00–DATA03 CKS

DATA00 : USER PICTURE Gain Flag

01H

DATA01 : RED Gain Flag

01H

DATA02 : RED Gain

E0H : -32
|
FFH : -1
00H : 0
|
20H : +32

DATA03 : RED Bias

E0H : -32
|
FFH : -1
00H : 0
|
20H : +32

ACK

6FH UA1 UA2 10H 02H DATA00 DATA01 CKS

DATA00 : USER PICTURE Gain Flag

01H

DATA01 : RED Gain Flag

01H

08. GREEN Gain Data

Function

The external control equipment changes the
GREEN gain data of the display. (This com-
mand will be received only when COLOR
TEMP is set for USER 1-4.)

Transmission Data

CFH UA1 UA2 11H 04H DATA00–DATA03 CKS

DATA00 : USER PICTURE Gain Flag

01H

DATA01 : GREEN Gain Flag

02H

DATA02 : GREEN Gain

E0H : -32
|
FFH : -1
00H : 0
|
20H : +32

DATA03 : GREEN Bias

E0H : -32
|
FFH : -1
00H : 0
|
20H : +32

ACK

6FH UA1 UA2 11H 02H DATA00 DATA01 CKS

DATA00 : USER PICTURE Gain Flag

01H

DATA01 : GREEN Gain Flag

02H

09. BLUE Gain Data

Function

The external control equipment changes the
BLUE gain data of the display. (This command
will be received only when COLOR TEMP is
set for USER 1-4.)

Transmission Data

CFH UA1 UA2 12H 04H DATA00–DATA03 CKS

DATA00 : USER PICTURE Gain Flag

01H

DATA01 : BLUE Gain Flag

03H

DATA02 : BLUE Gain

E0H : -32
|
FFH : -1
00H : 0
|
20H : +32

DATA03 : BLUE Bias

E0H : -32
|
FFH : -1
00H : 0
|
20H : +32

ACK

6FH UA1 UA2 12H 02H DATA00 DATA01 CKS

DATA00 : USER PICTURE Gain Flag

01H

DATA01 : BLUE Gain Flag

03H

10. GAMMA Gain Data

Function

The external control equipment changes the
GAMMA gain data of the display.

Transmission Data

CFH UA1 UA2 13H 03H DATA00–DATA02 CKS

DATA00 : USER PICTURE Gain Flag

01H

DATA01 : Gamma Gain Flag

09H

DATA02 : D-Gamma

00H : OFF
01H : ON

ACK

6FH UA1 UA2 13H 02H DATA00 DATA01 CKS

DATA00 : USER PICTURE Gain Flag

01H

DATA01 : Gamma Gain Flag

09H