59

34. SET CONDITION Inform

Function

The display informs the external control equip-
ment of the set’s condition information for re-
quests of the set’s condition information by the
external control equipment.

Transmission Data

0FH UA1 UA2 40H 00H CKS

ACK

6FH UA1 UA2 40H 17H DATA00–DATA22 CKS
* Accumulated set usage time display

DATA12

Bit0 (LSB)
|
Bit7

DATA13

Bit0
|
Bit7

DATA14

Bit0
|
Bit3 (MSB)
Bit4–7 : 0 fixed

* Microprocessor version display
Display example VER 1.0

DATA15

Bit0(LSB)
|
Bit3 (MSB)
Bit4 (LSB)
|
Bit7 (MSB)

* Current time display

1 character is expressed in 4 bits.

DATA16

Bit0
|
Bit3
Bit4
|
Bit7

DATA17

Bit0
|
Bit3
Bit4
|
Bit7

DATA18

Bit0
|
Bit3
Bit4
|
Bit7

DATA19

Bit0
|
Bit3
Bit4
|
Bit7

DATA20

Bit0
|
Bit3
Bit4
|
Bit7

DATA21

Bit0
|
Bit3
Bit4
|
Bit7

DATA22

Bit0 :

0 : Power management OFF
1 : Power management ON

Bit1 :

0 : Wireless remote control OFF
1 : Wireless remote control ON

Bit2 :

0 : Timer OFF
1 : Timer ON

Bit3–7 : 0 (fixed)

The set’s accumula-
tive time in 5 digits is
displayed with 4 bits
per digit and the first
digit is displayed from
Bit 0 of DATA12.

Microprocessor version
decimal point and first
right digit

Microprocessor version
first digit

Seconds 1’s digit

Seconds 10’s digit

Minutes 1’s digit

Minutes 10’s digit

Hours 1’s digit

Hours 10’s digit

Day 1’s digit

Day 10’s digit

Month 1’s digit

Month 10’s digit

Year 1’s digit

Year 10’s digit

Appendix

35. SIGNAL Inform

Function

The display informs the external control equip-
ment of the input signal information for requests
of input signal information by the external con-
trol equipment.

Transmission Data

0FH UA1 UA2 3EH 00H CKS

ACK

6FH UA1 UA2 3EH 04H DATA00–DATA03 CKS

DATA00

Bit7–4: Displays the 10's digit of the hori-

zontal frequency. (0 to 9)

Bit3–0: Displays the 10's digit of the hori-

zontal frequency. (0 to 9)

DATA01

Bit7–4: Displays the decimal point and the

first right digit of the horizontal fre-
quency. (0 to 9)

Bit3:

Horizontal sync polarity display
0 : Negative
1 : Positive

Bit2 :

Vertical sync polarity display
0 : Negativ
1 : Positive

Bit1,0: 0 (fixed)

DATA02

Bit7–4: Displays the 10's digit of the verti-

cal frequency. (0 to 9)

Bit3–0: Displays the 1's digit of the vertical

frequency. (0 to 9)

DATA03

Bit7–4: Displays the decimal point and the

first right digit of the vertical fre-
quency. (0 to 9)

Bit3–0: 0 (fixed)
''00H'' is output when there is no signal.