Appendix – NEC PlasmaSync 42PD3 User Manual

Page 56

Advertising
background image

56

P

LASMA

M

ONITOR

23. H-WIDTH Gain Data

Function

The external control equipment changes the H-
WIDTH (vertical expansion ratio) of the display.
(This command will be received only when multi
screen is ON.)

Transmissin Data

CFH UA1 UA2 20H 03H DATA00–DATA02 CKS

DATA00 : USER POSITION Gain Flag

09

DATA01 : H-WIDTH Gain Flag

04H

DATA02 : H-WIDTH Gain

80H : -128
|
FFH : -1
OH : 0
|
7FH : +127

ACK

6FH UA1 UA2 20H 02H DATA00 DATA01 CKS

DATA00 : USER POSITION Gain Flag

09

DATA01 : H-WIDTH Gain Flag

04H

24. TIMER SWITCH

Function

The external control equipment changes the
timer on/off switching of the display.

Transmissin Data

CFH UA1 UA2 02H 01H DATA00 CKS

DATA00 :

0 : RESERVE OFF
1 : RESERVE ON

ACK

6FH UA1 UA2 02H 01H DATA00 CKS

DATA00 :

0 : RESERVE OFF
1 : RESERVE ON

17. H.POSITION Gain Data

Function

The external control equipment changes the H.
POSITION gain data of the display.

Transmission Data

CFH UA1 UA2 1AH 03H DATA00–DATA02 CKS

DATA00 : USER POSITION Gain Flag

03H

DATA01 : H.POSITION Gain Flag

02H

DATA02 : H.POSITION Gain

C0H : -64
|
FFH : -1
00H : 0
|
40H : +64

ACK

6FH UA1 UA2 1AH 02H DATA00 DATA01 CKS

DATA00 : USER POSITION Gain Flag

03H

DATA01 : H.POSITION Gain Flag

02H

18. PHASE Gain Data

Function

The external control equipment changes the
clock phase of the display. (This command will
be received only when AUTO PICTURE is
OFF.)

Transmission Data

CFH UA1 UA2 1BH 03H DATA00 DATA01
DATA02 CKS

DATA00 : USER POSITION Gain Flag

03H

DATA01: PHASE Gain Flag

03H

DATA02: PHASE Gain

00H:0
|
1FH:31

ACK

6FH UA1 UA2 1BH 02H DATA00 DATA01 CKS

DATA00 : USER POSITION Gain Flag

03H

DATA01 : PHASE Gain Flag

03H

19. CLOCK Gain Data

Function

The external control equipment changes the
division ratio of the display. (This command will
be received only when AUTO PICTURE is
OFF.)

Transmission Data

CFH UA1 UA2 1CH 03H DATA00–DATA02 CKS

DATA00 : USER POSITION Gain Flag

03H

DATA01 : CLOCK Gain Flag

04H

DATA02 : CLOCK Gain

E0H : -32
|
FFH : -1
00H : 0
|
20H : +32

ACK

6FH UA1 UA2 1CH 02H DATA00 DATA01 CKS

DATA00 : USER POSITION Gain Flag

03H

DATA01 : CLOCK Gain Flag

04H

22. V-HEIGHT Gain Data

Function

The external control equipment changes the V-
HEIGHT (horizontal expansion ratio) of the dis-
play. (This command will be received only when
multi screen is ON.)

Transmissin Data

CFH UA1 UA2 1FH 03H DATA00–DATA02 CKS

DATA00: USER POSITION Gain Flag

09

DATA01: V-HEIGHT Gain Flag

03H

DATA02: V-HEIGHT Gain

80H : -128
|
FFH : -1
0H : 0
|
7FH : +127

ACK

6FH UA1 UA2 1FH 02H DATA00 DATA01 CKS

DATA00 : USER POSITION Gain Flag

09

DATA01 : V-HEIGHT Gain Flag

03H

Appendix