Default Settings

4-19

- Cell:

172.26.1.cell#

- Partition:

172.26.2.cell#

-

Subnet mask: 255.255.0.0

-

Gateway: 0.0.0.0 or 172.26.1.250, depending on the management firmware

implementation

Loss of all knowledge of multiple cell partitions. That is, the number of partitions can
be the same as the number of cells, where each partition consists of one cell.

Loss of many partition settings, such as SSL certificates.

You need to update IP addresses and update or verify other settings manually to be the
correct values for your system. Refer to

4.5.2 Updating Network Settings

, other portions

of this document, and the Service Processor Troubleshooting and Upgrade Guide for
more information.

Before restoring default settings, be sure that the partition is powered down. Restore
only one Service Processor at a time.

When you restore default settings, a countdown to restart management firmware begins
on the EXPRESSSCOPE® Monitor LCD, with the following options:

Restart immediately by pressing OK.

Wait for the countdown to complete before restarting.

Remove AC power, such as when you intend to power up in a new environment.

Caution

Do not remove AC power unless the partition is shut down.