2. Click Update Status to check progress while tests are executing. The current status

is updated with the current test ID, the number of tests completed of the total to run,
and the number of errors encountered. When tests complete, the label on the
button changes to Run Diagnostics, and the results are displayed.

Use the event log (refer to

3.5.5 Event Log

) and the sensor readings (refer to

3.5.4

Sensor Readings

) Web pages for additional diagnostic information about errors that

occurred during the tests.

3.5.23. Management Firmware Updates

You can display the current management firmware revision levels and update
management firmware for all cells in a partition that are powered on. All cells in a
partition should have the same firmware level. If you add a cell with a different firmware
level to a partition, the firmware is updated on the cell.

Note: The MLAN address remains the same when management firmware is updated.

Figure 3-22

shows the partition management firmware updates page.