Installing the new water heater (cont’d), Venting – Reliance Water Heaters 606 User Manual

Page 13

Advertising
background image

Installing the New Water Heater (cont’d)

13

absence of local codes, with the National Electrical

Code, ANSI/NFPA 70 (current edition).

6. Replace the wiring junction cover using the screws

provided.

Venting

All vent gases must be completely vented to the outdoors of

the structure (dwelling).

Wiring Diagram

5. The water heater must be electrically “grounded” by

the installer. The unit will not operate unless it is prop-

erly grounded. For complete grounding details and all

allowable exceptions, refer to local codes or in the

WARNING

Obstructed or deteriorated vent systems may present seri-

ous health risk or asphyxiation.

WARNING

The vent outlet must connect to the water heater exhaust out-

let. The vent inlet piping must connect to the water heater air

inlet. Both the water heater connections are clearly marked.

Failure to read this instruction can result in DEATH, SERIOUS

BODILY INJURY, OR PROPERTY DAMAGE.

WARNING

To insure proper venting of this gas-fired water heater, the

correct vent pipe diameter must be utilized. Any additions of

other gas appliances on vent with this water heater will

adversely affect the operation of the water heater.

WARNING

The vent pipe from the water heater must be 3

″″ diameter

vent pipe and must slope upward

1

8

inch per five linear feet.

CAUTION

Label all wires prior to disconnection when servicing con-

trols. Wiring errors can cause improper and dangerous

operation. Verify proper operation after servicing.

WARNING

Failure to have required clearances between water heater

and combustible material will result in a fire hazard.

MIN. RISE

1

8

PER FIVE FEET