Installation Checklist

BEFORE OPERATING THE WATER HEATER:
1. Check the gas line for leaks.

a. Use a soapy water solution. DO NOT test for gas leaks

using a match or open flame.

b. Brush the soapy water solution on all gas pipes, joints

and fittings.

c. Check for bubbling soap. This means you have a leak.

Turn “OFF” gas and make the necessary repairs.

d. Recheck for leaks.

e. Rinse off soapy solution and wipe dry.

2. Is the new temperature-pressure relief valve properly

installed and piped to an adequate drain? See “Temperature-

Pressure Relief Valve” section.

3. Are the cold and hot water lines connected to the water

heater correctly? See “Water Piping” instructions in the

“Installing the New Water Heater” section.

Installing the New Water Heater (cont’d)

MODEL RATING PLATE

4. Is the water heater completely filled with water? See “Filling

the Water Heater” instructions in the “Installing the New

Water Heater” section.

5. Will a water leak damage anything? See the “Locating the

New Water Heater” section.

6. Is there proper clearance between the water heater and any-

thing that might catch fire? See the “Locating the New Water

Heater” section.

7. Do you have adequate ventilation so that the water heater

will operate properly? See “Combustion Air and Ventilation”

in the “Locating the New Water Heater” section.

8. Is the vent piping properly secured? See “Venting” instruc-

tions in the “Installing the New Water Heater” section.

9. Is there proper clearance between the vent pipe and any-

thing that might catch fire? See “Venting” instructions in the

“Installing the New Water Heater” section.

10. Is the vent pipe properly sloped and does the vent terminate

outdoors? See “Venting” instructions in the “Installing the

New Water Heater” section.

11. Do you need to call your gas company to check the gas pipe

and its hookup?

COLD WATER INLET

HOT

WATER

OUTLET

TEMPERED

WATER

OUTLET

SHUTOFF

VALVE

TEE

DRIP LEG

(Sediment trap)

PIPE CAP

EXHAUST

VENT TO

OUTDOORS

GAS

SUPPLY

TEMPERATURE-

PRESSURE RELIEF

VALVE

DISCHARGE PIPE

(Do not cap or plug)

PROVIDE A 6

″″ AIR

GAP BETWEEN THE

END OF THE

DISCHARGE PIPE

AND DRAIN

INTAKE FOR

COMBUSTION

AIR

FLUE PRODUCTS

DISCHARGE PIPE

AIR INTAKE PIPE

Vacuum Relief

required by

some codes

(refer to local

codes)

SHUTOFF VALVE

SUITABLE FOR WATER (POTABLE)
HEATING AND SPACE HEATING

AUTOMATIC STORAGE WATER HEATER
FOR DIRECT VENT INSTALLATION
ELECTRICAL RATING: VOLTS 115/HZ60/AMPS 2