Installing the New Water Heater (cont'd)

Venting (cont'd)

INSTALLATION SHOWING USE OF PVC, ABS OR

CPVC PIPE FOR INLET AND OUTLET VENT PIPING:

Inlet piping through any type wall.

EXTERIOR WALL

SILICONE

SEALER

SILICONE SEALER

SCREW

SCREW

SCREW

SCREW

SCREEN AT

OUTLET

FLUE MOUNTING

ADAPTOR

VENT CAP MUST

BE POSITIONED

DOWNWARD

1

1

2

″″ MIN. EXTENSION

THROUGH

EXTERIOR WALL

FLUE MOUNTING ADAPTOR

CONNECTING VENT TO BLOWER

1. If making an immediate horizontal run of vent off the

blower, one 3

″ PVC inlet and one 3″ PVC (ABS for 75

Gal. Models and 50 Gal. 65,000 Btu/Hr Models) outlet

Schedule 40 street elbows are required. Place the elbow

in the required direction on the blower and using 3 sheet

metal screws, attach the elbow.

2. If there is to be a vertical run of vent from the blower, the

3

″ PVC inlet and the 3″ PVC (ABS for 75 Gal. Models

and 50 Gal. 65,000 Btu/Hr Models) outlet pipes must

be attached to the blower and venting hood, using 6

sheet metal screws.

CAULK

JOINTS

CAULK

JOINTS

VENT TO

OUTDOORS

INTAKE FOR

COMBUSTION AIR

FLUE PRODUCTS

DISCHARGE PIPE

AIR INTAKE

PIPE

INSTALLATION SHOWING USE OF (OPTIONAL)

DELUXE HORIZONTAL VENT KIT:

Typical installation.

If this concentric flue, through the wall type of venting sys-

tem is preferred, the vent kit can be ordered from the

Service Parts Dept. under kit #9002749. See also pages 34

to 37. Installation instructions are provided with the kit.

VENTING THROUGH A ROOF

Two 3

″ inlet and outlet PVC Schedule 40 45° vent caps are

supplied.

A 5’ section of 3

″ ABS Schedule 40 outlet vent pipe (75 Gal.

Models and 50 Gal. 65,000 Btu/Hr Models only) is sup-

plied. (More may be required and must be supplied locally).
1. The water heater requires its own (separate) venting

system.