WARNING

Toxic chemicals such as used for treatment of boilers or

non-potable water heating appliances shall never be

introduced into a potable water space heating system.

WARNING

This water heater shall not be connected to any heating

systems or component(s) previously used with a non-

potable water heating appliance.

If this water heater is also used for space heating applica-

tions, all piping and components connected to the water

heater shall be suitable for use with potable water.

Typical Installation

6

COLD WATER INLET

HOT WATER OUTLET

TEMPERED

WATER OUTLET

EXHAUST

VENT TO

OUTDOORS

GAS

SUPPLY

TEMPERATURE-

PRESSURE RELIEF

VALVE

MIXING

VALVE

DISCHARGE PIPE

(Do not cap or plug)

PROVIDE A 6

″″ AIR GAP

BETWEEN THE END OF

THE DISCHARGE PIPE

AND DRAIN

7' POWER CORD

(Factory supplied)

INTAKE FOR

COMBUSTION

AIR

FLUE PRODUCTS

DISCHARGE PIPE

AIR INTAKE PIPE

Vacuum Relief required

by some codes

(refer to local codes)

SHUTOFF VALVE

NOTE: To protect against untimely corrosion of hot and cold

water fittings, it is strongly recommended that di-electric

unions or couplings be installed on this water heater when

connected to copper pipe.

*Certain models do not have these connection assemblies shipped with the water heater. They (Part #9001262) are available

through the manufacturer. See “Repair Parts” section for ordering information.
This appliance has been design certified as complying with American National Standard/CSA Standard for water heaters and

is considered suitable for:

Water (Potable) Heating: All models are “considered suitable for water (potable) heating.”
Water (Potable) Heating and Space Heating: Certain models are “considered suitable for water (potable) heating and space

heating.” Refer to the model and rating plate of the water heater.

WARNING

When the system requires water at temperatures higher

than required for other uses, the hot water system may

require a means such as a mixing valve to be installed

to temper the water at certain points of use. Some peo-

ple are more likely to be permanently injured by hot

water than others; these include the elderly, children,

the infirm, or the physically/mentally handicapped.

Before immersing yourself or anyone else in hot water,

be sure to check the water temperature. WARNING:

HOTTER WATER INCREASES THE RISK OF SCALD

INJURY. (Also see “Temperature Regulation” section)

Mixing valves are available at plumbing supply or hard-

ware stores. Follow manufacturers instructions for

installation of these valves.

*COLD (RETURN) RECIRCULAT-

ING LOOP CONNECTION MUST

BE INSTALLED ONLY IN THE

UPRIGHT POSITION

*HOT (OUTLET) RECIRCULATING

LOOP CONNECTION CAN BE

INSTALLED WITHIN 360° RADIUS

DIRECTION

OF FLOW

DIRECTION

OF FLOW

CHECK VALVE

MARKED WITH

DIRECTION OF

FLOW ARROW

HEAT TRAP

Some models are equipped with