Troubleshooting – Reliance Water Heaters 606 User Manual

Page 31

Advertising
background image

31

Troubleshooting

THERMOSTAT AND GAS SUPPLY CHECK

Is thermostat calling for heat?

Run (hot) water from heater and

turn adjustment knob higher.

Check using a manometer at

thermostat pressure tap.

Is there a minimum gas pressure

4

″ W.C. for natural gas or 10″

W.C. for propane (L.P.) gas?

GO TO SYSTEMS CHECK

SECTION, PAGE 32

Turn “ON” gas supply.

Call gas company to increase

gas pressure.

Yes

Yes

Yes

No

Is gas being supplied to the

thermostat?

No

WARNING

This troubleshooting guide has been supplied for use by

qualified service personnel who have a complete under-

standing of both electricity and gas.

WARNING

Label all wiring before disconnecting any wiring; to

ensure correct reconnection. Failure to follow this

instruction could cause improper and possible danger-

ous operation, resulting in DEATH, SERIOUS BODILY

INJURY, OR PROPERTY DAMAGE.