Locating the new water heater, Facts to consider about the location – Reliance Water Heaters 606 User Manual

Page 7

Advertising
background image

Facts to Consider About the

Location

You should carefully choose an indoor location for the new water

heater, because the placement is a very important consideration

for the safety of the occupants in the building and for the most

economical use of the appliance. This water heater is not for use

in manufactured (mobile) homes or outdoor installation.
Whether replacing an old water heater or installing the water heater

in a new location, the following critical points must be observed.
1. The location selected should be indoors as close as practical to

the vent termination point, and as centralized with the water pip-

ing system as possible. The water heater, as all water heaters, will

eventually leak. Do not install without adequate drainage provi-

sions where water flow will cause damage.

2. If vented through an outside wall or through the roof using 3

″ vent

piping, the total vent run (vertical and horizontal) cannot exceed

a total of 45 feet with one elbow. If more elbows are required,

the venting distance must be reduced 5 feet for every 90° elbow.

See page 15 for vent chart.

3. Vent piping cannot slope downward and horizontal runs require

1

8

″ per five foot rise. All horizontal runs require adequate support

at 3

1

2

foot intervals and vertical runs supported at 5 foot intervals.

4. The water heater requires its own (separate) venting system. It

cannot be connected to an existing vent pipe or chimney. It must

terminate to the outdoors. Whenever possible terminate the vent

on the leeward side of the building through an outside wall. Note:

Condensation may be created, at times, as the combustion gases

exit the vent cap and discoloration of surfaces in proximity to

the vent cap may occur.

5. The water heater comes equipped with a 7 foot power cord which

can be used to connect to a 110/120 volt power source if (1) local

codes allow, and (2) there is a three prong receptacle available.

7

Locating the New Water Heater

6. The location selection must provide adequate clearances

for servicing and proper operation of the water heater.

Figure 1

WARNING

This water heater must not be installed directly on carpeting.

Carpeting must be protected by a metal or wood panel

beneath the appliance extending beyond the full width and

depth of the appliance by at least 3 inches (76.2mm) in any

direction, or if the appliance is installed in an alcove or clos-

et, the entire floor must be covered by the panel. Failure to

heed this warning may result in a fire hazard.

WARNING

Minimum clearances between the water heater and combustible

and non-combustible construction are: 0 inches from sides, 0

inches from back, 6 inches from front of jacket to closet door

and 12 inches from top of jacket to combustible and non-com-

bustible material. Minimum vent clearance: 0 inches. Provide 24

inches front clearance for servicing and adequate clearance

between the jacket top and ceiling for servicing the flue area.

WARNING

Propellants of aerosol sprays and volatile compounds,

(cleaners, chlorine based chemicals, refrigerants, etc.) in

addition to being highly flammable in many cases, will also

change to corrosive hydrochloric acid when exposed to the

combustion products of the water heater. The results can

be hazardous, and also cause product failure.

WARNING

INSTALLATION IN AREAS WHERE FLAMMABLE LIQUIDS

(VAPORS) ARE LIKELY TO BE PRESENT OR STORED

(GARAGES, STORAGE AND UTILITY AREAS, ETC):

Flammable liquids (such as gasoline, solvents, propane (LP)

or butane, etc.) or other substances (such as adhesives, etc.),

all of which emit flammable vapors, may be improperly

stored or used in such areas. The gas water heater ignitor

or main burner can ignite such vapors. The resulting flash-

back and fire can cause death or serious burns to anyone in

the area, as well as property damage.

If installation in such areas is your only option, then the

installation must be accomplished in a way that the ignitor

and main burner flame are elevated from the floor at least

18 inches. While this may reduce the chances of flammable

vapors from a floor spill being ignited, gasoline and other

flammable substances should never be stored or used in the

same room or area containing a gas water heater or other

open flame or spark producing appliance.

Also, the water heater must be located and/or protected so

it is not subject to physical damage by a moving vehicle.

NOTE: Flammable vapors may be drawn by air currents

from other areas of the structure to the appliance.

CAUTION

WATER HEATERS EVENTUALLY LEAK: Installation of the water

heater must be accomplished in such a manner that if the tank or

any connections should leak, the flow of water will not cause

damage to the structure. When such locations cannot be avoid-

ed, a suitable drain pan should be installed under the water

heater. Drain pans are available at your local hardware store.

Such a drain pan must have a minimum length and width of at

least 2 inches greater than the water heater dimensions and must

be piped to an adequate drain. Drain pan depth must allow for

access to the outer doors for servicing the ignitor and burner.

WARNING

Do not use an extension cord. If there is not a suitable recepta-

cle with ground and/or local codes prohibit use of a power cord,

field wiring must be provided.

WARNING

The power direct vent water heater requires its own (separate)

venting system. It cannot be connected to an existing vent pipe

or chimney. It must be terminated to the outdoors. Failure to

properly install the venting system can result in asphyxiation, a

fire or explosion and can cause DEATH, SERIOUS BODILY IN-

JURY, OR PROPERTY DAMAGE.