Installing the new water heater (cont’d), Warning – Reliance Water Heaters 606 User Manual

Page 19

Advertising
background image

19

Connecting the gas piping to the gas control valve of the

water heater can be accomplished by either of the two

methods shown.

SEDIMENT TRAP
A sediment trap shall be installed as close to the inlet of the

water heater as practical at the time or water heater instal-

lation. The sediment trap shall be either a tee fitting with a

capped nipple in the bottom outlet or other device recog-

nized as an effective sediment trap. If a tee fitting is used, it

shall be installed in conformance with one of the methods

of installation shown.

Installing the New Water Heater (cont’d)

GAS PIPING WITH

FLEXIBLE CONNECTOR

GAS PIPING WITH ALL BLACK IRON PIPE TO

GAS CONTROL

WARNING

Contaminants in the gas lines may cause improper oper-

ation of the gas control valve that may result in fire or

explosion. Before attaching the gas line be sure that all

gas pipe is clean on the inside. To trap any dirt or foreign

material in the gas supply line, a drip leg (sometimes

called a sediment trap) must be incorporated in the pip-

ing. The drip leg must be readily accessible. Install in

accordance with the “Gas Piping” section. Refer to the

current edition of the National Fuel Gas Code, ANSI

Z223.1, also referred to as NFPA 54.

WARNING

Use pipe joint compound or teflon tape marked as being resis-

tant to the action of petroleum [Propane (L.P.)] gases.

WARNING

The appliance and its gas connection must be leak tested

before placing the appliance in operation.

WARNING

The appliance and its individual shutoff valve must be

disconnected from the gas supply piping system during

any pressure testing of that system at test pressures in

excess of

1

/

2

pound per square inch (3.5kPa).

The appliance must be isolated from the gas supply pip-

ing system by closing its individual manual shutoff valve

during any pressure testing of the gas supply piping sys-

tem at test pressures equal to or less than

1

/

2

pound per

square inch (3.5kPa).

GAS SUPPLY PIPING

MANUAL

SHUTOFF

VALVE

GAS

CONTROL

VALVE

GROUND JOINT

UNION

BLACK PIPE

DRIP LEG

(SEDIMENT

TRAP)

CAP

3

″ MIN.

GROUND JOINT

UNION (OPTIONAL)

MANUAL

SHUTOFF

VALVE

GAS

CONTROL

VALVE

GAS SUPPLY PIPING

FLEXIBLE GAS CONNECTOR

LABELED AS COMPLYING

WITH ANSI STANDARDS

DRIP LEG

(SEDIMENT

TRAP)

CAP

3

″ MIN.

Advertising