General Safety (cont’d)

3

WARNING

This water heater must not be installed directly on carpeting.

Carpeting must be protected by a metal or wood panel beneath

the appliance extending beyond the full width and depth of the

appliance by at least 3 inches (76.2mm) in any direction, or if

the appliance is installed in an alcove or closet, the entire floor

must be covered by the panel. Failure to heed this warning may

result in a fire hazard.

WARNING

Do not install in a confined area such as a closet, unless you provide

ventilation air as shown in the “Locating The New Water Heater”

section. Never obstruct the flow of ventilation air. If you have any

doubts or questions at all, call your gas company. Failure to provide

ventilation air can result in a fire or explosion and can cause

DEATH, SERIOUS BODILY INJURY, OR PROPERTY DAMAGE.

WARNING

If this water heater will be used in beauty shops, barber shops,

cleaning establishments, or self-service laundries with dry clean-

ing equipment, it is imperative that the water heater or water

heaters be installed so that combustion and ventilation air be

taken from outside these areas. Refer to the “Locating The New

Water Heater” section of this manual and also the current edition

of the National Fuel Gas Code, ANSI Z223.1, also referred to as

NFPA 54 for specifics provided concerning air required.

WARNING

The power direct vent water heater requires its own (separate)

venting system. It cannot be connected to an existing vent pipe

or chimney. It must be terminated to the outdoors. Failure to

properly install the venting system can result in asphyxiation, a

fire or explosion and can cause DEATH, SERIOUS BODILY IN-

JURY, OR PROPERTY DAMAGE.

WARNING

No vent damper installation is compatible with this power vented

water heater design. No vent damper, whether it is operated ther-

mally or otherwise is to be installed on this power vented water

heater. Alteration of any part of the factory-furnished vent assembly

could result in improper operation due to restriction of flue gases,

spillage of flue gases and may cause carbon monoxide poisoning.

WARNING

1. The appliance and its individual shutoff valve must be dis-

connected from the gas supply piping system during any pres-

sure testing of the gas system at test pressures in excess of

1

2

pound per square inch (3.5kPa).

2. The appliance must be isolated from the gas supply piping

system by closing its individual manual shutoff valve during

any pressure testing of the gas supply piping system at test

pressures equal or less than

1

2

pound per square inch

(3.5kPa).

WARNING

Soot build-up indicates a problem that requires correction be-

fore further use. Turn “OFF” gas to water heater and leave “OFF”

until repairs are made, because failure to correct the cause of

the sooting can result in a fire or explosion causing DEATH, SE-

RIOUS BODILY INJURY, OR PROPERTY DAMAGE.

WARNING

The water heater must be properly vented outdoors. Never op-

erate the water heater unless it is vented to the outdoors and

has adequate air supply to avoid risks of improper operation, ex-

plosion or asphyxiation.

WARNING

Vent termination must not be within 4 feet of any items such as

gas meters, gas valves or other gas regulating equipment.

WARNING

Obstructed or deteriorated vent systems may present a serious

health risk or asphyxiation.

WARNING

Chemical vapor corrosion of the flue and vent system may occur

if air for combustion contains certain chemical vapors. Spray can

propellants, cleaning solvents, refrigerator and air conditioner

refrigerants, swimming pool chemicals, calcium and sodium chlo-

ride, waxes, bleach, and process chemicals are typical compounds

which are potentially corrosive.

WARNING

Minimum clearances between the water heater and combustible

and non-combustible construction are: 0 inches from sides, 0 inch-

es from back, 6 inches from front of jacket to closet door and 12

inches from top of jacket to combustible and non-combustible

material. Minimum vent clearance: 0 inches. Provide 24 inches

front clearance for servicing and adequate clearance between the

jacket top and ceiling for servicing the flue area.

WARNING

HYDROGEN GAS: Hydrogen gas can be produced in a hot water

system that has not been used for a long period of time (generally

two weeks or more). Hydrogen gas is extremely flammable and

explosive. To prevent the possibility of injury under these condi-

tions, we recommend the hot water faucet be opened for several

minutes at the kitchen sink before any electrical appliances which

are connected to the hot water system are used (such as a dish-

washer or washing machine). If hydrogen gas is present, there will

probably be an unusual sound similar to air escaping through the

pipe as the hot water faucet is opened. There must be no smoking

or open flame near the faucet at the time it is open.

WARNING

INSULATING JACKETS: When installing an external water heater

insulation jacket on a gas water heater:

a. DO NOT cover the temperature-pressure relief valve.

b. DO NOT put insulation over any part of the top of the gas water

heater.

c. DO NOT put insulation over the gas control valve or gas control

valve/burner cover, or any access areas to the burner.

d. DO NOT let insulation around the gas water heater to get with-

in 8 inches of the floor (access for servicing the burner).

e. DO NOT remove operating instructions, and safety related warn-

ing labels and materials affixed to the water heater. DO obtain

new warning and instruction labels from the manufacturer for

placement on the jacket directly over the existing labels.

Failure to heed this will result in the possibility of a fire or explosion.

WARNING

Flood damage to a water heater may not be readily visible or imme-

diately detectible. However, over a period of time a flooded water

heater will create dangerous conditions which can cause DEATH,

SERIOUS BODILY INJURY, OR PROPERTY DAMAGE. Call a qual-

ified service technician or contractor to replace a flooded water

heater. Do not attempt to repair the unit! It must be replaced!

CAUTION

WATER HEATERS EVENTUALLY LEAK: Installation of the water heater

must be accomplished in such a manner that if the tank or any connec-

tions should leak, the flow of water will not cause damage to the structure.

For this reason, it is not advisable to install the water heater in an attic or

upper floor. When such locations cannot be avoided, a suitable drain pan

should be installed under the water heater. Drain pans are available at

your local hardware store. Such a drain pan must have a minimum length

and width of at least 2 inches greater than the water heater dimensions

and must be piped to an adequate drain. Drain pan depth must allow for

access to the outer doors for servicing the ignitor and burner.