Omega WI8XX-U User Manual

Page 43

Advertising
background image

4.3.6 Controller Setup (continued)

Below are the definitions of terms used in the Controller Setup page.

A) Setup:

Clicking on the options shown, allows user to modify the different parameters

shown under this menu (see Section 4.3.7. Setup Page for more details).

B) Monitor:

Scrolling: If checked, the Meter will display data from all the End Devices.

Otherwise, it only displays data from the End Device specified on Device ID.

End Device ID: Address/ID of the End Device that will be display on the Meter.

C) Transmission Power:

PID (Network ID): The Personal Network ID (0 to 65535). In parenthesis is the

firmware version of the radio module. The firmware version is also shown on a

label attached to the Meter (see Figure 3.1).

The Meter always has an address of 0.

Channel: Choose the operation channel defined in IEEE 802.15.4 for the

sensor network.

Transmission Power: This determines the signal power transmitted by the

Meter. The options are 10 dBm and 20 dBm.

Please refer to local regulations for the allowed maximum transmission

power.

For additional details, please refer to Appendix F.

D) Miscellaneous:

iSeries Version: The firmware version of the Meter. The firmware version is

also shown on a label attached to the Meter (see Figure 3.1).

Changes made on the Controller Setup page will take place after clicking

the Reset Controller button or simply power recycling the meter.