4.4 Telnet Setup

In the "Network Setup" page, under the Terminal Server section, set the TCP

Connections to 1 to 5 other than 0, and use a telnet emulation program to

connect to the Meter (using Port 2000). The command can be sent to query the

Meter and get a response back.

Table 4.1 List of ASCII / Telnet Commands (01 indicates End Device #1)

Command

Description

Response

*SR01a\r

Reading from Sensor1 (process)

66F

*SR01b\r

Reading from Sensor2 (ambient)

68F

*SR01e\r

Readings from Sensor1

66F

and Sensor2

68F

*SR01f\r

Sequence number (0-255)

90

*SR01g\r

Sensor type

230

*SR01h\r

Signal strength (0-100%)

49

*SR01i\r

Success rate (0-100%)

100

*SR01j\r

Battery voltage (mV)

2810

*SR01k\r

Device status (hex, msb on the left hand side)

12th bit: set to enable alarm control

8th bit: set to enable display

7th bit: set when Open detected

1100

6th bit: set when Lost detected

*SR01l\r

Expected sample rate in seconds

120

(also known as update time)

*SR01n\r

Name

Conf Room

*SR01o\r

Readings from Sensor1 in Celsius

19

*SR01p\r

Readings from Sensor2 in Celsius

20

*SR00z\r

Display all information

1 230 P66 F A68 F 90 49 100 2810 1100 120 Conf Room

2 230 P69 F A69 F 80 44 100 2810 1100 120 Engr Lab

6 230 P72 F A73 F 173 75 100 3110 1100 120 Server Room

7 230 P70 F A72 F 202 72 100 3450 1100 120 Clean Room