Access control, 1 end device parameters (continued), 10 access control – Omega WI8XX-U User Manual

Page 61: Figure 4.25 access control

Advertising
background image

55

4.3.9.1 End Device Parameters (continued)

If the end character for instance is 20 (Hex representation of space), the data will

then appear as: T75F T74F

If nothing is set for the "Remote End Char" field, the Meter will then forward the

data to the LAN with no characters followed.

Offset: If it’s determined that the readings are slightly off, the user can manually

assign numerical values to adjust the readings for temperature. The unit must be

in degree C.

Display: To enable or disable numerical display on the Meter’s Front Panel. By

default, the box is checked (enabled).

Alarm: To enable or disable alarms for that particular sensor. By default, the box

is checked (enabled).

Sensor 2

This is the field to modify the parameters for the ambient sensor.

Update: Saves changes.

Cancel: Ignores all the changes and goes back to the "End Device Setup" page.

Reset Device: Reset the End Device’s readings and status. Its data will be

cleared immediately.

4.3.10 Access Control

This section describes the "Access Control" page of the Wireless System Web

interface. This page allows the users to set up the network and security

parameters of the Wireless System.

At the initial entrance to the "Access Control" page you may be prompted for the

LOGIN Password (see Figure 4.6) prior to an ADMINISTRATOR Password.

Figure 4.25 Access Control

ACCESS CONTROL

ACCESS CONTROL

http://192.168.1.200

Address

Main Menu

Login Password 12345678

Admin Password 00000000

IP Address 192.168.1.200

Gateway Address 0.0.0.0
Subnet Mask 255.255.255.0

MAC Address 00:03:03:00:21:D9

Host Name wis21d9

Save Reset

Network Reset