4.3.7.4 Analog Output Retransmission

This menu will appear only if you have the Analog Output Option installed

in your Meter.

Figure 4.18 Analog Output Retransmission

Retransmission: When enabled, the input data will be scaled based on Input

Low and Input High and will be outputted. If the input reaches high value the

output will be 10V or 20mA. If the input reaches low value, the output will be

0V or 0mA.

Voltage/Current: Select the output to be Voltage (0-10V) or Current (0-20mA).

Input Low: The minimum input value scaled for Output Low.

Output Low: Output Voltage or Current represented by Input Low.

Input High: The minimum input value scaled for Output High.

Output High: Output Voltage or Current represented by Input High.

Input High

Output Low

Retransmission

Voltage/Current

Enabled
Voltage

0.00

Input Low

0

Output High

10.00

Min. 0V

Max. 10V

1000

Main Menu

SETUP

Analog Output Retransmission

SETUP

http://192.168.1.200

Address

Cancel

Update

43