30

7

Verify that "Signal Wait" is flashing
together with the time display and
then start the playback of the
recording source.

Recording starts as soon as the CDR-201A
receives signals from the recording source.

Notes on the signal synchronous recording

• When the level synch function is turned on

during analog recording, the track numbers are
updated automatically as soon as audible sound
is detected after 2 seconds or more of silence.

• If “Signal Wait” continues for 1 minute, signal

synchronous recording is cancelled and playback
is stopped.

• When "D.In Unlock" appears in the front display

during the signal synchronous recording (digital
input), the CDR-201A cancels the recording
mode and enter to the recording standby state.

4

Adjust the recording level.

Refer to page 24, step 4 "Adjust the recording
level."

5

Stop the playback of the recording
source.

6

Press the o REC button (or the remote
controller REC
o button)

The CDR-201A enters the input standby state,
"Signal Rec" appears in the display, and then
"Signal Wait" appears flashing alternately with
the time display.

CDR-201A

RC-448C

Synchronous recording by input signal detection
(Signal synchronous recording)

REC

REC