General purpose control – TOA Electronics CP-66 User Manual

Page 102

Advertising
background image

General Purpose Control

Station may be restricted from access to this function. This
function can control other equipments by employing the

Data Transmitting and Receiving Units.

Select the required type of output.

(Mode 1) One-shot make output (500/50 contacts)

Example: Door remote and VTR control
Note:

Operation performed even when all link circuits

are occupied.

(Mode 2) Make/break output (512/100 contacts)

Dial

00 ~ 99

(000 ~ 511)

and the make output is sent out.

Dial

00 ~ 99

(000 ~ 511)

and the break output sent out.

Example: In/out annunciation, Prescription annunciation.

(Mode 3) 8-selectable one-shot make output (9 units)
Dial

1 ~ 9

1 ~ 8

Unit No. Contact No.

and one contact out of 8 selectable make outputs is
obtained for about 1 or 2 seconds.

Example: VTR control

(Mode 4) 8 selectable make output and/or decimal output

(A) 8 selectable make output (64/9 units)

Dial

1~9

(01~64)

Unit No.

1~ 8 , 0

(Clear)

Condition No.

and one of the 8 relay outputs is made. "Clear" opera-
tion makes all 8 relays break.

Example:

Destination indication, room condition

indication, ITV control

(B) Decimal output

Dial

1~9

(01~64)

Unit No.

0 ~ 9

Condition No.

and the condition is indicated numerically.

Example: Destination indication, room condition

(Mode 5) 4 decimal digits output
Dial

1 ~ 9

0000 ~ 9999

Unit No.

4 decimal digits

and 4 decimal digits are indicated.

Fig. 1

Control with one-shot make output

Fig. 2

Lamp on/off indication panel

Fig. 3 VTR control with 8-selectable one-shot make output

Fig. 4

8 selectable output type indication panel

Fig. 5

Decimal output type indication panel

Fig. 6

4 decimal digits type indication panel

Example: Prescription annunciation

Door
remote

control

Dial

00 ~ 49

(000 ~ 499)

and the relay output is made for 1 to 2 seconds.

—96—

Advertising