Master sub relationship, Automatic access to paging – TOA Electronics CP-66 User Manual

Page 78

Advertising
background image

Master Sub Relationship

Master/Substation associations are set up by using station

#200 as the programming station. Once these relationships
have been established, substations can then contact their

designated master stations by simply touch dialing

If TL-600S Handset substation is used, it can be connected

to its designated master station by simply picking up a

handset.

With respect to this function, the stations in the system are

divided into two categories; master stations and substations.
Any master station can be connected to any other station

in the system. However, substations can initiate calls only

to. specific master stations. This is done by single touch

dialing, and will only connect the substation to one specific

master.

Also, one master station can have 2 or more substations.

To register this function, dial

Confirmation tone

Substation No. paired off with the master

at the master station. This allows the master station to be

Note.

Once a certain station number has been desgination as a

substation by No. 200 programming, the single digit
dialing is impossible even when the master station is
connected to that number.

Automatic Access To Paging

Substation

Master Station

Handset substation

Single Digit Registration of Substation

Master Station

Substation Number

Substation

This function requires "single digit dialing registration for
handset station" as well as No.200 programming at time of

installation.

A paging call can be placed over the specified zone by
simply lifting the handset.

A paging response is possible by simply lifting the handset.

Paging call

Paging call

Fig. 1

Paging response

Response to

a paging call

Fig. 2

Tie-line

—72—

connected to the substation when

is pressed.

Advertising