Tektronix 070-9180-01 User Manual

Page 51

Advertising
background image

Command Descriptions

Option 01 VXI Interface Module User Manual

3–27

N/A

[ROUTe:]CONFigure:JOIN
[ROUTE:]CONFigure
[ROUTe:]CLOSe:MODE

Disconnect the commons of all sections of a scanner module. This command is
supported for VX4330, VX4372, and VX4374 Modules.

In these examples the Option 01 is installed on a VX4330 Module. Two addi-
tional VX4330 Modules are installed in consecutive slots to the right of this
module. A VX4374 is installed in the slot to the right of the third VX4330.

Command

Response

route:configure:

disjoin m1

Disconnect the commons of the first VX4330.

rout:conf:disj m4

Disconnect the commons of the two sections of the VX4374.

[ROUTe:]CONFigure

:JOIN <module_name>,<section_list>

N/A

All sections on all scanner modules are disjoined.

This command is supported for VX4330, VX4374, and VX4372 Modules. The
section numbers specified in the <section_list> argument must be between 1 and
6 for VX4330 modules. Section numbers 1 and 2 are valid for VX4374 and
VX4372 Modules.

[ROUTe:]CONFigure:DISJoin,
[ROUTE:]CONFigure,
[ROUTe:]MODE

This command connects the commons of adjacent sections on scanner modules.
On VX4330 modules, if a section that is configured as a 4-wire scanner is joined
to a section that is configured as a 1-wire or 2-wire scanner, only the lower half
of the 4-wire scan common is connected. If a 4-wire section is joined to another
4-wire section, both halves of the 4-wire scan common are joined. Also for the

Limits

Related Commands

Description

Examples

Command Syntax

Query Syntax

*RST Value

Limits

Related Commands

Description

Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com