10 – Internal settings

Playback settings (PLAY SETUP)


U

se this screen to make settings related to playback.

GENERAL page

Make various settings related to the playback mode on this
page.

Play Mode

Set how the playback of takes and entries is handled using the
following buttons. This setting affects all modes except timeline
mode.

One Take button (default):

Only the currently selected take or playback is played back.

All Take button:

All the takes in the currently loaded session or all the entries
in the playlist are played back.

Repeat Mode

Turn repeat playback

ON

and

OFF

(default).

Follow BWF–J

Turn the BWF–J cue point function

ON

or

OFF

(default). This

setting can be made separately for each mode.
When the BWF–J cue point function is

ON

, operation will follow

BWF–J cue points set in sessions and takes. For details about
operation, see the following pages.
Timeline mode: page 45
Take mode: page 53
Playlist mode: page 70

CONTROL page

Make various settings related to the playback functions on this
page.

Auto Cue

Turn the auto cue function

ON

or

OFF

(default). If auto cue is

ON

,

whenever a take is changed or loaded, the unit will enter
playback standby at the point where sound first starts in the take.
When

Play Mode

is set to

One Take

and no sound is detected

before the end of the take, the unit stops at the start of the take.
When

Play Mode

is set to

All Take

and no sound is detected

before the end of the take, the unit continues detection in the
next take.
This setting affects all modes except timeline mode.

To set the auto cue start point detection level, touch the knob
area and use the DATA dial to change the value.
Options:

–72dB

,

–66dB

,

–60dB

,

–54dB

(default),

–48dB

,

–42dB

,

–36dB

,

–30dB

,

–24dB

Auto Ready

Turn the auto ready function

ON

or

OFF

(default).

If auto ready is

ON

, when playback of a take completes the unit

automatically stops at the beginning of the next take.
This setting affects all modes except timeline mode.

Inc. Play

Turn the incremental play function

ON

or

OFF

(default).

When incremental play is

ON

, press the PLAY key during

playback to move to the beginning of the next take and
continue playing, or press the STOP (RETAKE) key during
playback to move to the beginning of the next take and pause
playback.
This setting affects all modes except timeline mode.

PLAY Inhibit Time

This sets a time interval during which playback of the same take
(entry) cannot be restarted.
The following keys and commands are disabled (excluding flash
start keys/commands for other takes/entries) for the duration of
this setting. The PLAY key on the front panel of the unit, the
PLAY key, flash start keys and fader start function of the TASCAM
RC-HS32PD remote control (sold separately), and play and flash
start commands from external controllers (RS-422, RS-232C,
parallel, keyboard).
Setting range: 0–1000 msec (100 msec intervals), Inf (during
playback the affected keys are disabled for this amount of time)
Default value: 0 msec

NOTE

When the

PLAY Inhibit Time

item is set to

Inf

, the incremental play

function is automatically fixed to OFF and cannot be switched to ON.

Sync and time code settings (SYNC T/C)


Make various settings related to audio synchronization and time
code on this page.
This screen has five pages:

CLOCK

,

SYNC

,

T/C

,

SETUP

and

I/O

.

Touch the tabs at the bottom of the screen to open the

orresponding page.

c

CLOCK page

View various clock status information and select the clock used
for synchronization.

STATUS

The top section shows the project sampling frequency and clock
synchronization status.
The bottom section shows digital input signal status in the

ormat

D-INx

(

x

shows the channels), as follows.

f

Digital input signal status

Display

Locked

Locked (xx.xxx kHz)

When sampling rate
conversion is ON

Locked

(xx.xxx

kHz

FsCnv)

Unlocked

Unlocked (xx.xxx kHz)

No signal

Unlocked (no signal)

No audio signal present

Not Audio

Other Cbit information
differs from the actual
operation mode

Unmatched Cbit