10 – internal settings, T/c page, Setup page – Tascam HS-4000 User Manual

Page 75

Advertising
background image

TASCAM HS-4000

75

10 – Internal settings


T/C page

Make settings related to time code on this page.

Set to free run

Set to jam sync (and free once)

STATUS

This shows the time code generator mode of the unit and the
time code frame type of the currently loaded project.

GENERATOR

The top line shows the current time code generator.
The bottom line shows the user bits (

UB

).

Touch the

GENERATOR

item

EDIT

button or the user bits (

UB

)

display area to open the

T/C USER BITS

screen.

When the time code generator is in free run mode, touch the

RESTART

button to reset the time code of the time code

generator to the start time.

TC IN

The top line shows the time of the input time code and the
frame type. The bottom line shows the user bits (

UB

) of the input

time code.
In Free Run mode, touch the

CAPTURE

button to capture the

current time code and set it as the time code of the time code
generator.
If the time code generator mode is Free Once or Jam Sync, the
capture status (

WAITING

) indicator lights green when waiting

for time code, and it turns off after time code is captured.

START TIME

When you touch the

GENERATOR

item

RESTART

button, the

time when the time code restarts is shown.
Touch the

START TIME

item

EDIT

button or the

START TIME

display area to open the

START TIME

screen.

SETUP page

Make settings related to the time code generator on this page.

STATUS

This area shows the currently loaded project’s time code frame
type.

TC GEN MODE

Use the buttons to set the time code generator mode.

FREE RUN button:

The time code generator runs on its own.

FREE ONCE button:

After the input time code is captured once, the unit starts
free run mode.

TIME OF DAY button:

If you conduct any of the following operations, the time will
be captured from the internal clock and free run mode will
start.
• Turn the power on
• Set

TC GEN MODE

to this mode

• Reset the internal clock

JAM SYNC button:

When time code is input, the unit synchronizes to it. If time
code input is interrupted, the unit enters free run mode.

REGEN button:

The unit synchronizes to the input time code.

REC RUN button (default):

The time code generator only functions during recording. At
all other times, the time code generator stops.

Frame Type

Set the time code frame type of the currently loaded project.
Setting buttons:

23.976F

,

24F

,

25F

,

29.97DF

(default),

29.97ND

,

30DF

,

30ND