10 – internal settings, Sync page – Tascam HS-4000 User Manual

Page 74

Advertising
background image

74

TASCAM HS-4000

10 – Internal settings

MASTER

Use the buttons to select the master clock to use.

INT button (default):

Use this unit’s internal clock.

WORD button:

Synchronize with the word clock input through the
WORD/VIDEO IN connector.

VIDEO button:

Synchronize with the video clock input through the
WORD/VIDEO IN connector.

DIN–1, DIN–2 buttons:

Synchronize with the clock of the digital signal selected as
the input of DIGITAL IN 1/2.
You cannot select an input as the master clock if the
sampling rate converter is ON for that input.

NOTE

A

mark appears on the button of the currently active master clock.

If synchronization from an external clock is interrupted, the unit’s

internal clock becomes active. In this case, the

mark appears on

the INT button to show that it has become the active clock, and the

mark appears on the button of the selected external clock that was lost.


SYNC page

Make settings related to synchronization on this page.

STATUS

Shows the status of the currently loaded project’s sampling
frequency and clock synchronization.

Play Fs

When playing a take with a sampling frequency of 48 kHz, 48 kHz
pull-up or 48 kHz pull-down, the unit can be made to
synchronize with an external clock by setting it to play back with
pull-up or pull-down.
Depending on the combination of Project sampling frequency
and Play Fs settings, the unit will operate with the sampling
frequency shown below (default:

OFF

).

NOTE

Set this to

OFF

before recording.

Recording is not possible when set to

Pull-up +0.1%

or

Pull-down

–0.1%

. If you try to record when not

OFF

, “

Cannot REC

” appears in a

warning pop-up window.

TC Chase

Use to turn playback synchronized with timecode

ON

or

OFF

(default).
Set it to

ON

when you want to match the timing of this unit’s

audio with a timecode master device (audio recorder, video or
built-in time code generator).
You can also set timecode offset (TC Offset) with the timecode
master device. Touch the

EDIT

button to open the

CHASE

Offset

screen where you can set the offset value in a range

between −23:59:59.29 and +23:59:59.29 (default: 00:00:00.00).

NOTE

TC Chase can also be turned ON and OFF by pressing the SHIFT and CALL
keys at the same time.

TC Rechase

Turn this function, which re-synchronizes when synchronization
with timecode becomes inaccurate,

ON

or

OFF

(default).

When set to

OFF

, after synchronizing once, input time code is

ignored and the unit operates in free run mode.
When set to

ON

, set the amount of inaccuracy that triggers

rechasing.
To set the amount of inaccuracy that triggers rechase, touch the
knob and turn the DATA dial to select a value in frames of

1/3

,

1

,

2

(default),

5

or

10

.

Master TC

Set whether the unit synchronizes with the built-in timecode
generator or with timecode input from another device.

Internal button:

Synchronize with the built-in generator.

External button (default):

Synchronize with timecode input from another device.


Play Fs setting

Project

sampling

frequency OFF Pull-down

Pull-up

48 kHz

48 kHz

48 kHz−0.1% 48 kHz+0.1%

48 kHz

pull-down

48 kHz - 0.1% Not possible 48 kHz

48 kHz pull-up 48 kHz+0.1% 48 kHz

Not possible

All others

Project
sampling
frequency

Not possible Not possible

Advertising