Routine Care and Adjustments

Position the Label Sensor

13163L Rev. 3 5/20/2004

Z4Mplus/Z6Mplus User Guide

85

To adjust the reflective sensor, complete these steps:

1.

See

Figure 38

. Open the printhead assembly by pressing the printhead open lever.

2.

Locate the reflective sensor positioning lever.

3.

Move the reflective sensor positioning lever across the width of the media until the
reflective sensor aligns with the gap or notch. The glow of the red light assists in the
proper placement of the reflective sensor.

4.

Close the printhead assembly.

Caution • Ensure that the printhead is fully open and engaged in the up position. If the
printhead is not latched in the up position, it could fall on your hand during the
procedure.