Configuration

Configuration and Calibration LCD Displays

INIT FLASH MEM

Initialize Flash Memory

Caution • Perform this operation only when it is necessary to erase all previously
stored information from the FLASH memory. Press PLUS (+) to bypass this
function.

1.

Press SELECT to select the parameter.
If your printer is set to require a password, you are prompted to enter the password.

2.

Enter the password, then press SELECT.

3.

Press PLUS (+) to select YES.
The display asks

INITIALIZE FLASH?

.

4.

Press PLUS (+) to select

YES

.

The front panel LCD asks

ARE YOU SURE?

.

5.

Press MINUS (–) to select

NO

and cancel the request. The

INITIALIZE FLASH

prompt is displayed.
or
Press PLUS (+) to select

YES

and begin initialization. Depending on the amount

of free FLASH memory, initialization may take up to one minute to complete.

6.

Press SETUP/EXIT followed by SELECT. If initialization is still in process,
the front panel display flashes back and forth between the phrases

CHECKING E: MEMORY

and

PRINTER IDLE

.

When initialization is complete, the printer automatically exits the configuration
mode and the front panel displays

PRINTER READY

.

7.

Press SELECT to continue with the next prompt.

SENSOR PROFILE

Sensor Profile
The media sensor profile may be used to troubleshoot registration problems that may be
caused when the media sensor detects preprinted areas on the media or experiences
difficulty in determining web location. If the sensitivity of the media and/or ribbon
sensors MUST be adjusted, use the manual calibration procedure.

Figure 32 • Media Sensor Profile

1.

Press SELECT to select the parameter.

2.

Press PLUS (+) to print a media sensor profile.

3.

Press SELECT to deselect the parameter.

Table 9 • Printer Parameters and Other LCD Displays (Sheet 6 of 15)