Rs-232 serial data port – Zebra Technologies Z6Mplus User Manual

Page 121

Advertising
background image

Data Connections

Serial Data Port

13163L Rev. 3 5/20/2004

Z4Mplus/Z6Mplus User Guide

103

RS-232 Serial Data Port

The connection for this standard interface is made through the female DB-9 connector on the
rear panel. A DB-9 to DB-25 interface module is required for all RS-232 connections through
a DB-25 cable (see

RS-232 Interconnections Using a DB-25 Cable on page 105

for details).

For all RS-232 input and output signals, the printer follows both the Electronics Industries
Association’s (EIA) RS-232 specifications and the Consultative Committee for International
Telegraph and Telephone (CCITT) V.24 standard signal level specifications.

Table 17

shows the pin configuration and function of the rear panel serial data connector on

the printer.

Table 17 • Serial Data Connector Pin Configuration

Pin Number

Name

Description

1

Not connected

2

RXD

Receive data—data input to printer

3

TXD

Transmit data—data output from printer

4

DTR

Data terminal ready—output from printer

5

SG

Signal ground

6

DSR

Data set ready—input to printer

7

RTS

Request to send—output from printer

8

CTS

Clear to send—input to printer

*9

+5 V DC

+5 VDC

* This pin is also available as a +5 VDC power source at 750 mA. To enable this capability, a

jumper on the computer’s main logic board needs to be installed on JP1, pins 2 and 3.

Note •

An interface module is required for RS-422/RS-485 interface support

(see

RS-422/RS-485 Interconnections on page 106

).

Advertising