Printer Setup

Select a Communication Interface

Parallel Port Communicating using the parallel port (see

Figure 8

) does not require special

settings. The serial settings do not affect the parallel port. Refer to

Parallel Data Port

on page 107

for further information.

Figure 8 • Communicating Using a Parallel Port

Cable Requirements

Data cables must be fully shielded and fitted with metal or metallized connector shells.
Shielded cables and connectors are required to prevent radiation and reception of electrical
noise.

To minimize electrical noise pickup in the cable:

• Keep data cables as short as possible.
• Do not bundle the data cables tightly with the power cords.
• Do not tie the data cables to power wire conduits.

Printer

Computer

36-pin

male

25-pin

male

PC

25-pin

female

10 ft. (3 mm) maximum

Note •

Zebra printers comply with FCC Rules and Regulations, Part 15 for Class B Equipment

using fully shielded, 6.5 ft (2 m) data cables. Use of unshielded cables may increase radiation
above the Class B limits.

Note •

RS-422 and RS-485 applications should use twisted shielded pairs as recommended in

the TIA/EIA-485 Specification.