4 robot language description, 4-1 mova, 4-2 movi – Yamaha SRCP User Manual

Page 104

Advertising
background image

8-

6

8

ROBOT LANGUAGE

8-4 Robot Language Description

8-4

Robot Language Description

8-4-1 MOVA

Function:

Moves to a point specified by a point number (Moves to an absolute
position relative to the origin point).

Format:

MOVA <point number>, <maximum speed>

Example:

MOVA 51, 80
Moves to P51 at speed 80.

Explanation:

This command moves the robot to a position on the absolute coordinates
whose origin position is defined as 0.
The robot starts moving when all axes enter the positioning-completed
pulse range, and stops when all axes reach the OUT valid position.
(1) Point number

The point number is a number designated to each point from 0 to
999, a total of 1000 points, and used to create point date in PNT
(point) mode. When a character "P" is entered here for special use, a
point variable defined by the "P" statement is set as the point number.
(See "8-4-12 P".)

(2) Maximum speed

The maximum speed can be set to any level between 1 and 100. If
the execution speed in OPRT mode is 100, then 100 will be equal to
2000 mm/sec. (when PRM44=2000).

8-4-2 MOVI

Function:

Moves a distance specified by a point number from the current position.

Format:

MOVI <point number>, <maximum speed>

Example:

MOVI 10, 80
Moves an amount equal to point data P10 from the current position at
speed 80.

Explanation:

This command moves the robot on the relative coordinates with the cur-
rent position viewed as 0.
The robot starts moving when all axes enter the positioning-completed
pulse range, and stops when all axes reach the OUT valid position.
(1) Point number

The point number is a number designated to each point from 0 to
999, a total of 1000 points, and used to create point date in PNT
(point) mode. When a character "P" is entered here for special use, a
point variable defined by the "P" statement is set as the point number.
(See "8-4-12 P".)

(2) Maximum speed

The maximum speed can be set to any level between 1 and 100. If
the execution speed in OPRT mode is 100, then 100 will be equal to
2000 mm/sec. (when PRM44=2000).