1 communication parameter specifications, Communica tion with pc – Yamaha SRCP User Manual

Page 178

Advertising
background image

11-

2

11

COMMUNICA

TION WITH PC

11-1 Communication Parameter Specifications

11-1 Communication Parameter Specifications

The communication parameters on the PC should be set as follows. For the setting procedure, refer to
the computer operation manual.

■ Baud rate

9600 bps

■ Data bit length

8 bits

■ Stop bit length

1 bit

■ Parity check

On

■ Parity setting

Odd

■ Control method

XON/XOFF software control

(X parameter)

(Effective)

■ Communication method

Full duplex

■ Sync method

Asynchronous method

■ Return key transmission

CR code

■ CR code reception

For CR/LF reception : Return + line feed

For CR reception

: Return

* If the above parameter settings are not possible due to your equipment specifications, the robot

controller settings can be changed by changing PRM47 (communication parameter settings)
from the TPB.

PRM47 settings (default value: 0)

bit

Function

Selection

15 to 9

8

7 to 4

3

2

1 to 0

Reserved

Termination code

Transmission speed

Data bit length

Stop bit length

Parity check

Always set to 0.

0: CR + LF

0: 9600bps

4: 2400bps

1: 300bps

5: 4800bps

2: 600bps

6: 9600bps

3: 1200bps

7 to 15: Cannot be set

1: CR

0: 8 bits

0: 1 bit

1: 7 bits

1: 2 bits

0: Odd

1: Even

2 to 3: Non

Example: To set the data bit length to "7 bits" and the parity check to "Non", enter "10" for PRM47,

which is given by

0000000000001010 (binary) = 10 (decimal)

c

CAUTION

Be sure to use a cable which conforms to specifications listed in "11-2 Communication Cable Specifications".
The settings will be invalid if other cables such as POPCOM communication cables or those having different
specifications are used.
After changing the parameters, turn the power off and then turn it on again to enable the settings.
The TPB can be used even if the parameters have been changed.

Advertising