1-2 robot number list, 1-3 led display, Specifica tions – Yamaha SRCP User Manual

Page 237

Advertising
background image

15-

3

15

SPECIFICA

TIONS

15-1 SRCP sereis

Error detection items

Ambient temperature

Storage temperature

Ambient humidity

Noise immunity

Peripheral options

Overcurrent, overload, wire breakage, runaway, etc.

0 to 40

°C

-10 to 65

°C

35 to 85%RH (no condensation)

Conforms to IEC61000-4-4 Level 2

TPB (Ver. 12.50 or later), IC memory card, support software POPCOM

*1)

The regenerative unit (RGU-2) is required to operate a load with large inertia or a robot model specified by YAMAHA.

General
specification

Others

Protective
function

c

CAUTION

Specifications and external appearance are subject to change without prior notice.

15-1-2 Robot number list

Each robot model has an identification number as listed in the table below. After you initialize the
parameters, enter the correct robot number that matches the robot model actually connected to the
controller.

Robot model

Robot number

MR12T

512

MR16T

516

MR16TH

536

MR20F

520

MR20FH

521

MR25F

525

MF50

550

c

CAUTION

Production of the MR20F was discontinued in March, 2006.
Using the robot with wrong setting may cause malfunctions.

15-1-3 LED display

The table below shows the specifications of the operation status LED on the front panel of the con-
troller.

LED display

Not lit

Lit in green

Lit in red

Flashes green (0.5 sec.) and red (0.5 sec.)

Flashes green (1.5 sec.) and red (0.5 sec.)

Robot or controller operation status

The power is off or fuse is blown.

Servo motor is on. (Ready to operate)

Error occurred. (Alarm is being issued.)

Emergency stop

Emergency stop is canceled. (Servo off)

Advertising