1-4 program error message, Message t ables – Yamaha SRCP User Manual

Page 212

Advertising
background image

12-

4

12

MESSAGE T

ABLES

12-1 Error Messages

12-1-4 Program error message

Error No.

40

Error No.

41

Error No.

42

Error No.

43

Error No.

44

Error No.

45

Message

Cause

Action

Message

Cause

Action

Message

Cause

Action

Message

Cause

Action

Message

Cause

Action

Message

Cause

Action

stack overflow

q Seven or more successive CALL statements were used within a CALL statement.
w In the program called as a subroutine by a CALL statement, a jump was made to

another program by a JMP or JMPF statement.

q Reduce the number of CALL statements used in a CALL statement to 6 or less.
w Review the program.

cannot find label

The specified label cannot be found.

Create the required label.

cannot find step

The specified step cannot be found.

Check whether the step number is correct.

cannot find PGM

The specified program cannot be found.

Check whether the program number is correct.

PGM memory full

The total number of steps in all programs has exceeded 3000.

Delete unnecessary programs or steps.

step over

The total number of steps in one program has exceeded 255.

Delete unnecessary steps or divide the program into two parts.

Advertising