1 srcp sereis, 1-1 basic specifications, Specifica tions – Yamaha SRCP User Manual

Page 236

Advertising
background image

15-

2

15

SPECIFICA

TIONS

15-1 SRCP sereis

15-1 SRCP sereis

15-1-1 Basic specifications

Model

Specification item

SRCP-10

SRCP-20

SRCP-05

Basic
specifi-
cations

Axis
control

Memory

Command
mode

I/O

I/O

interface

Normal

mode

Max. power consumption

External dimensions

Weight

No. of controllable axes

Control method

Position detection method

Speed setting

Acceleration setting

Servo adjustment

ROM

RAM

No. of program steps

No. of programs

No. of points

No. of multi tasks

Point teaching

Auxiliary memory unit

Normal mode

I/O

Type

Pulse train mode

Mode

Frequency

Serial communication (RS-232C)

200V, 200V, 200V, 200V, 200V, 200V,

400VA

600VA

1000VA

400VA

600VA

1000VA

W78

H250

D157mm

1.5kg

Single-phase AC200 to 230V

within

±10% 50/60Hz

1 axis

AC full digital servo

Magnetic linear scale

1 to 100% in 1% steps

Automatically set according to robot type and payload.

Acceleration can also be set by parameter (1 to 100% in 1% steps)

Handled with parameters (special). Servo gain, current limit, etc.

256K bytes (with CPU incorporated)

128K bytes with lithium battery backup (5-year life)

3000 steps or less in total, 255 steps/program

100

1000 points

4

MDI (coordinate value input), teaching playback, direct teaching

IC memory card is available as TPB option.

Robot operation by dedicated command input

1. phase A/phase B

2. pulse/code

3. CW/CCW

One of the above should be selected.

Line driver (+5V)

Maximum 2 Mpps (line driver)

1. Data transmit/receive, parameter setting and robot operation by
communication

commands

2. Data transmit/receive, parameter setting, point teaching and robot

operation by TPB (option)

General-purpose: 8 points, dedicated input: 8 points

General-purpose: 5 points, dedicated output : 3 points, open collector output

General-purpose: 8 points, dedicated input: 5 points

General-purpose: 5 points, dedicated output: 3 points, open collector output

PULS+, PULS-, DIR+, DIR-

One of the above should be selected.

Line driver (+5V)

PA+, PA-, PB+, PB-, PZ+, PZ-, PZM+, PZM-

phase A/phase B

Line driver (+5V)

External DC +24V input for sequence input/output

Relay output (for 24V/300mA brake), 1 ch; Uses power supply for sequence I/O

Connectable to DC24V normally-closed sensor; Uses power supply for
sequence I/O

Normally-closed contact input (origin return not required after emergency stop
is released)

RS-232C, 1ch (for communication with TPB or PC)

CC-Link, DeviceNet, Ethernet, PROFIBUS

Sequence (I/O) input

Sequence (I/O) output

Sequence (I/O) input

Sequence (I/O) output

Name

Type

Mode

Name

Type

Mode

Feedback pulse output

SRCP-05A

SRCP-10A

SRCP-20A

100W or less 200W or less 600W or less 100W or less 200W or less 600W or less

Single-phase AC100 to 115/200 to 230V

within

±10% 50/60Hz

Applicable motor capacitance

*1)

Power supply voltage

Pulse train

mode

Command pulse
input

Power supply for sequence I/O

Brake output

Origin sensor input

Emergency stop input

Serial interface

Network (option)

Advertising